Diaton tonometer is a handheld device that measures IOP through the eyelid & completely
satisfies present-day  requirements of diagnostic equipment.

 
 

Spheres of diaton tonometer application

  • ophthalmology (including children's)
  • general medical practice
  • optometry
  • neurology
 
           
 

 

Innovative approach to IOP measurement opens up wide medical
opportunities and indisputable benefits both for doctors &  patients:


for doctors:

  • Accurate results
  • Wide range of medical opportunities
  • Quick & efficient  procedure of measuring (IOP measurement takes several seconds)
  • Сreates an image of a modern doctor working in an up-to-date equipped medical center
  • Wide medical opportunities
  • Low dispensable materials' expenses


for patients:

  • No contact to the cornea
  • No risk of infection
  • No anesthesia drops
  • No pain
  • No need to take out contacts
 

 

Transpalpebral "diaton" tonometer is effective and irreplaceable in complicated medical cases:

  • Can measure IOP even in the presence of viral infections, allergic reactions, dry eye syndrome, contraindications for corneal tonometry
  • Can serve as non-invasive day monitoring tool while selecting the adequate hypotensive medical treatment
  • Can measure IOP  on patients after corneal surgeries
  • Сan measure IOP with contact lenses on
  • Can measure IOP on immobilized patients
  • Screening tool for elevated IOP by PCPs
  • Trained family members  can monitor IOPs of glaucoma patients at home

 

Features diaton ShiotzTonometer Air-jet Tonopen Icare
No contact with the cornea +        
Portability +  +   + +
Displays independence from cornea's crookedness.
+
       
Digital IOP indication +   + + +
Measurement in sitting position +   + + +
Measurement in reclining position + +   +  
Short-time measurement +   +   +
Sterilization is not required +   +   +
Anesthesia is not required +   +   +
Dispensable materials are not required +   +    
No need to take out the contact lens + - - - -

 

Comparative tests of diaton tonometer and Goldman tonometer give the evidence of high reliability thatdiaton tonometer guarantees.

SPECIFICATIONS

 
Measurement range, mm Hg 5-60
Measurement error Limit of the admissible measurement error in the range, not more:
from 5 to 20 mm Hg - ±2 mm Hg;
from 20 to 60 mm Hg - ±10%
The time of a single measurement, s, not more 3
Supply voltage, V 3
Number of measurements using one battery set, not less 1500
Service life, not less 5
Weight, g 89
Dimensions, mm, not more 174 х 26 х 20